Steam boiler, hot water boiler, thermal oil boiler, hot air boiler, electric boiler, gas boiler, oil boiler, biomass boiler, coal-fired boiler, biogas boiler, steam generator, pressure vessel, enamel reactor, stainless steel reactor, steam storage tank. Taikang boiler, Dakang boiler, Yinchen boiler. Henan boiler, China boiler.
We also have a variety of installation services and supporting auxiliary machine accessories. There is always one for you to choose.
AboutUsThe furnace body has a true three-pass structure, and the flue gas circulates three times in the furnace. It is not a false three-pass design (two passes in the furnace + energy saver), and it is not a direct exhaust type! The flame burns at a slight positive pressure in the combustion chamber, with low combustion heat load and low emissions of harmful nitrogen oxides and NOx; the full edge butt weld has high reliability and low maintenance costs.
ENERGY CONSERVATION AND ENVIRONMENTAL PROTECTION
In view of the characteristics of biomass fuel combustion, this boiler adopts secondary air and a larger furnace volume, which can promote the fuel to burn fully and effectively in the furnace, achieving the purpose of energy saving and environmental protection..
THREE-RETURN STRUCTURE
The furnace body has a true three-pass structure, and the flue gas circulates three times in the furnace. It is not a false three-pass design (two passes in the furnace + energy saver), and it is not a direct exhaust type! The flame burns in the combustion chamber with a slight positive pressure, the combustion heat load is low, and the emission of harmful substances such as nitrogen oxides and NOx is low; high reliability and low maintenance costs. THREADED SMOKE PIPE
This boiler adopts threaded smoke pipe, which increases the heating area and has the characteristics of fast startup and ignition. AUTOMATIC LOADING
It adopts feeding machine for transmission and automatic feeding to reduce the labor intensity. It can use biomass pellet fuel or coal* as fuel.. FEWER MECHANICAL PARTS
The mechanical equipment components of the boiler have been adapted for decades, with stable performance and low failure rate, which reduces the subsequent maintenance costs and is more convenient to use and maintain. AUTOMATIC CONTROL
With the fully automatic control system, you only need to set the required pressure/temperature and other parameters to achieve fully automatic control: automatic start and stop of the burner, automatic water replenishment and other operations; reduce the labor intensity of boiler operators and reduce misoperation caused by human factors. SAFETY INTERLOCK PROTECTION
Equipped with multiple interlocking protections such as over-temperature*, over-pressure, water shortage, full water, leak detection*, flameout, etc. to ensure safe and reliable operation. HEAT RECOVERY
The flue gas waste heat recovery device* is installed after the boiler to reduce the exhaust gas temperature and improve the thermal efficiency of the boiler; it also reduces fuel consumption and saves operating costs.
*:Optional configuration
Warm reminder: This product is illegal under Chinese laws and regulations, please choose carefully.
Model |
Rated Evaporatio Capacity (t/h) |
Rated Evaporation Pressure(Mpa) |
Thermal Efficiency(%) |
Consumption (Coal-fired kg/h) |
Consumption (Biomass fuel kg/h) |
LHG0.1-0.7-AII(SCII) | 0.1 | 0.7 | ≥83% | 20-30 | 40-50 |
LHG0.2-0.7-AII(SCII) | 0.2 |
0.7 |
≥83% | 30-40 | 60-70 |
LHG0.3-0.7-AII(SCII) | 0.3 | 0.7 | ≥83% | 40-50 | 80-90 |
LHG0.5-0.7-AII(SCII) | 0.5 | 0.7 | ≥83% | 50-60 | 100-120 |
LHG0.7-0.7-AII(SCII) | 0.7 | 0.7 | ≥83% | 70-80 | 150-160 |
LHG1-0.7-AII(SCII) | 1 | 0.7 | ≥83% | 100-120 | 200-220 |
FUEL OPTIONS INCLUDE: Coal-fired、Biomass Fuel AND MORE. The calorific value of coal is 4500kcal/kg, and that of Biomass Fuel is 3000kcal/kg
Note: Due to technical updates, we cannot display all the latest parameters here. If we make changes, we will not modify them here. We have more models for you to choose from. If your needs are not found here, please contact us.